Sensing type |
Through-beam type |
---|
Light source |
Infrared LED(855nm) |
---|
Effective aperture angle(EAA) |
Within ± 2.5 ° when the sensing distance is greater than 3 m for both emitter and receiver. |
---|
Sensing distance |
Short - Long mode (setting switch or atLightCurtain) |
---|
Short mode |
0.2 to 8 m |
---|
Long mode |
0.2 to 15 m |
---|
Detection capability |
Ø 30 mm (hand-body) |
---|
Sensing target |
Opaque |
---|
Number of optical axes |
24 |
---|
Optical axis pitch |
25mm |
---|
Series connection |
Max. 4 SET (≤ 400 optical axes) |
---|
Power supply |
24 VDC ±20 %(ripple P-P: ≤10 %) |
---|
Current consumption |
Emitter: ≤106mA, receiver: ≤181mA |
---|
Safety related output: OSSD output |
NPN or PNP open collector Load voltage : ON - 24 VDC (except for the residual voltage), OFF - 0 VDC Load current : ≤ 300 mA Residual voltage : ≤ 2 VDC (except for voltage drop due to wiring) Load capability: ≤ 2.2 ㎌ Leakage current: ≤ 2.0 mA Wire resistance of load: ≤ 2.7 Ω |
---|
Auxiliary output(AUX 1/2) |
NPN or PNP open collector Load voltage: ≤ 24 VDC , Load current: ≤ 100 mA, Residual voltage: ≤ 2 VDC (except for voltage drop due to wiring) |
---|
Lamp output(LAMP 1/2) |
NPN or PNP open collector Load voltage: ≤ 24 VDC , Load current: ≤ 300 mA |
---|
Protection circuit |
Reverse power polarity, reverse output polarity, output short-circuit over-current protection |
---|
Safety-related functions |
Interlock (reset hold), external device monitoring (EDM), muting/override, Blanking (fixed blanking, floating blanking), reduced resolution |
---|
General functions |
Self-test, alarm for reduction of incident light level, mutual interference prevention |
---|
Others functions |
Change of sensing distance, switching to NPN or PNP, external test (light emission stops), auxiliary output (AUX 1, 2), lamp output (LAMP1, 2) |
---|
Synchronization type |
Timing method by RS485 synchronous line |
---|
Insulation resistance |
Over 20MΩ (at 500VDC megger) |
---|
Noise immunity |
The square wave noise (pulse width: 1㎲) by the noise simulator ±240VDC |
---|
Dielectric strength |
1,000VAC 50/60Hz for 1 minute |
---|
Vibration |
10 mm double amplitude at frequency of 5 to 150 Hz, 10 sweeps ni each X, Y, Z direction |
---|
Shock |
250 m/s² (≈ 25 G), pulse width 6 ms in each X, Y, Z direction for 100 times |
---|
Environment_Ambient illumination |
Sunlight: Max. 10,000lx, Incandescent lamp: Max. 3,000lx (received illumination) |
---|
Ambient temperature |
-30 to 60 ℃, storage: -30 ~ 70 ℃ (no freezing or condensation) |
---|
Ambient humidity |
35 to 85 %RH, storage: 35 to 95 %RH (non-freezing or non-condensation) |
---|
Protection structure |
IP65, IP67(IEC Standard), IP67G (JEM Standard), IP69K (DIN Standard) |
---|
Material |
Case: Aluminum, Front cover and sensing part: Polymethyl methacrylate, End cap: polycarbonate, Power I/O cable and connector cable: polyurethane (PUR) or polyvinyl chloride (PVC), Y type connector cable: polyvinyl chloride (PVC), lamp output cable and series connector cable: polyurethane (PUR), Top / Bottom adjustable bracket and Top / Bottom bracket: SUS304, Side adjustable bracket and Side bracket: nickel plated Zn |
---|
International standards |
UL 508, CSA C22.2 No. 14, ISO 13849-1 (PL e, Cat. 4), ISO 13849-2 (PLe, Cat. 4), UL 61496-1 (Type 4, ESPE), UL 61496-2 (Type 4, AOPDs), IEC/EN 61496-1 (Type 4, ESPE), IEC/EN 61496-2 (Type 4, AOPDs), IEC/EN 61508-1~-7 (SIL 3), IEC/EN 62061 (SIL CL 3) |
---|