Accuracy |
absolute accuracy: < ±0.1 % of the measurement range, Basic accuracy: < ±1 °C |
Configuration |
DIP switch |
Delivery state |
Setting parameters |
Output |
Configuration |
4...20 mA |
Setting parameters |
Sensor error detection |
Configuration |
enabled |
Setting parameters |
Output error level |
Configuration |
downscale |
Setting parameters |
Noise suppression |
Configuration |
50 Hz |
Setting parameters |
Step response time |
Configuration |
< 30 ms |
Setting parameters |
Start temperature |
Configuration |
-200 °C |
Setting parameters |
End temperature |
Configuration |
0 °C |
|
|
Delivery state |
Output: 4...20 mA // Sensor error detection: enabled // Output error level: downscale // Noise suppression: 50 Hz // Step response time: < 30 ms // Start temperature: -200 °C // End temperature: 0 °C |
Galvanic isolation |
Without isolation |
Long-term drift |
0 |
Power consumption, max. |
0.52 W |
Power consumption, typ. |
0.37 W |
Rail |
TS 35 |
Step response time |
Configurable, ≤ 30 ms, < 300 ms |
Temperature coefficient |
0,1 °C ⁄ °C, or, ≤0,01% des Messbereichs⁄°C |
Type of connection |
Screw connection |
Voltage supply |
24 V DC ± 30 % |